Deployment Use Cases
Real-world deployment scenarios for AquaSense smart water management -- from a single home tank to large-scale commercial and industrial installations.
Single Family Home
1 gateway + 1 coordinator + 2 sensorsBasic water management for a typical household with one overhead tank and one pump.
- Real-time tank monitoring
- Auto-fill when low
- Mobile app control
- Works offline via BLE
Multi-Tank Home
1 gateway + 1 coordinator + 4 sensors + 2 mesh routersMultiple tanks with a shared pump. Ideal for large villas or homes with separate overhead and ground-level tanks.
- Monitor up to 5 tanks
- Priority-based filling
- Shared pump management
- Zigbee mesh networking
Apartment Building
1 gateway + 1 coordinator + 20 sensors + 5 mesh routersLarge-scale residential deployment with centralized monitoring and fair water distribution across all units.
- 20+ tank monitoring
- Fair water distribution
- Centralized dashboard
- Zigbee mesh with routers
Commercial & Industrial
Multiple gateways + coordinatorsWater treatment plants, factories, and large commercial facilities requiring multi-gateway fleet management.
- Multi-gateway architecture
- Up to 8 independent Zigbee networks
- Fleet management
- Cloud analytics via MQTT
Direct Mobile Connection
Phone + 1 deviceThe simplest possible setup. Control a single device directly from your phone over BLE -- no gateway needed.
- BLE direct control from phone
- No gateway required
- Lowest cost entry
- Ideal for single tank
Single Tank Auto-Fill
3–5 devices: coordinator + sensor + actuatorFully automated, fully offline filling for one tank. Set thresholds and let the system handle the rest.
- Fully offline operation (no cloud)
- Threshold-based auto-fill
- Motor safety (max runtime 120 min cooldown)
- Fault detection and recovery
Multi-Tank Auto-Fill
5–10 devices: controller + 2–5 sensors + 1 actuatorShared pump fills multiple tanks using priority-based scheduling. Handles round-robin or simultaneous fill strategies.
- Priority-based round-robin or simultaneous fill
- Shared motor pump management
- Tank switch in ~35 seconds
- Motor max runtime 4 hours continuous
Motor Protection
1 controller + current sensorDedicated pump and motor monitoring with overcurrent, thermal, and dry-run protection.
- 6 motor types supported (single-phase, three-phase, DC, submersible, jet, centrifugal)
- Overcurrent, thermal, and dry-run protection
- <10ms relay switching, <100ms protection response
- Energy tracking and daily statistics